The Linked Tables Manager can't tell the profile

EnsureLinks, Check or another method called without a profile raises wkeNotConfigured with the message „No profile given, and the tables match no profile uniquely (DEV, TEST …).“ In the designer, the Profiles page says „The tables match no profile uniquely.“

Environment

WKL Forms Object Library with WklLinkManager, a configuration whose USysConnection names at least one profile, in ACCDB or ACCDE files or the Access Runtime.

Cause

Without an Environment argument and without the Environment property, the link manager takes the profile the tables are linked with now. It refuses to guess when that isn't clear:

  • No configured table is linked yet (a new front end, or the links were deleted).
  • The tables are linked half to one profile and half to another, for example after Relink of a single table, so two profiles match equally well.
  • The links point to sources that the configuration doesn't name for any profile (the configuration was changed after linking).

Linking to a guessed profile could connect a front end to production data, so the error is deliberate.

Resolution

  1. Name the profile at startup: EnsureLinks "PROD", or set Environment once (links.Environment = "PROD") before you call methods without an argument.
  2. To see what the tables are linked with, run Check with each profile (Debug.Print links.Check("DEV").Count, links.Check("TEST").Count) or open the designer's Check and synchronize page.
  3. Bring all tables to one profile with EnsureLinks "<profile>" (or Refresh all in the designer); afterward, calls without a profile work again.