Color scheme: Dark
You are here: start » en » Documentation » Data integration and data access » WKL Database Gateway » .NET client Wkl.Data.Gateway.Client—overview » Reference » Configuration (reference)

Configuration (reference)

Applies to version 0.2.1. The settings live in the application's configuration in the GatewayClient section (GatewayClientOptions.SectionName) and are validated when the application starts. If a setting breaks the rule in the “Valid” column, the application doesn't start, and the message names every setting that is wrong.

SettingDefaultValidMeaning
BaseAddress–Required; absolute address with https, with http (from 0.3.0) only for this computer (localhost, 127.0.0.1, ::1)Address of the service. Over http to another computer, the key would cross the network unencrypted; the client refuses this at startup and never sends such a request later either. If the service runs under a path (https://server/dataservice), the client adds the trailing slash itself
ApiKeyEnvironmentVariableWKL_GATEWAY_API_KEYnot emptyName of the environment variable that holds the key
ApiKeyHeaderX-Api-Keynot emptyHeader for the key; must match the service's Gateway:Security:ApiKeyHeader
CorrelationHeaderX-Request-Idnot emptyHeader for the correlation ID; must match the header the service reads (its default is also X-Request-Id), otherwise the service assigns its own ID
ReadTimeout15 sgreater than zero, at most 5 minTime limit for reading (ReadAsync)
WriteTimeout30 sgreater than zero, at most 5 minTime limit for a procedure call (InvokeAsync). The name says “write” because a procedure call is how the client writes; it applies to every call, though, including one to a procedure that only reads
MaxResponseBytes32 MiBgreater than zeroLargest response the client reads; a larger one ends with LimitExceeded if the service states the length in advance; otherwise reading stops at the limit and ends with Unavailable
MaxUrlLength2,000not negativeLongest address used for a read request. A longer one is sent as POST …/$query with the options in the body; 0 sends every read request with options that way. The default follows the smallest common limit (by default, IIS accepts a query string of at most 2,048 bytes), because the client doesn't know which host sits in front of the service

Time limits of the client and of the service. The service cancels a statement after its own time limit (default 30 s) and reports TimedOut. If the client's time limit is shorter (as it is for reading by default), the client stops waiting first and reports Unavailable; the statement keeps running in the service until it finishes or is canceled. If you expect long read requests, set ReadTimeout slightly above the service's time limit.

The key itself isn't a setting. Only the name of the environment variable is configured; the value is read for each request and never stored. A key in a configuration file is a key in the repository, in the container image, and in every backup of both.

Where to get it. You get the Wkl.Data.Gateway.Client package together with the data service, from your provider's package feed; it isn't on nuget.org. It brings the contract package Wkl.Data.Gateway.Contracts 0.6.0 as a dependency; both belong in the same package feed. This documentation describes the client against a data service with contract 0.6.0. An older service handles reading and calling the same way; what later contract versions add is then missing (see Changes).

en/wiki/data-conectivity/database-gateway/client/reference/configuration.txt · Last modified: by Wolfgang van der Stille