When entering asset data, the following field definitions must be considered.
| Field | Description |
|---|---|
| Asset No. | Asset numbers have a space between letter and number. |
| P&I | The number of the as-built P&I diagram of the site. |
| OU | The operating unit number can be found in the licensing flow diagrams. |
| Asset Status | Values: 1=„in operation“, 2=„in planning“, 3=„decommissioned“, 4=„not yet realized“ |
| Content inside/outside | Volume specification in liters. |
| VFA | If the volume is a VFA specification, the field contains „yes“. |
| Intake Volume | Flow rate in m³/h. |
| PermOpPressure inside/outside | Permissible operating pressure (design pressure) in bar. |
| Pressure Surge Resistant | empty=normal pressure, 1=„psr = X bar“, 2=„corresponds to psr = X bar“ |
| MaxWorkPressure inside/outside | Pressure during normal operation in bar. Range „X to Y“ possible. |
| Relief Valve Pressure | Relief valve response pressure in bar. |
| Zero Delivery Head | Zero delivery head of pumps against closed valves in bar. |
| PermOpTemp inside/outside | Permissible operating temperature in °C. |
| MaxWorkTemp inside/outside | Temperature during normal operation in °C. Range „X to Y“ possible. |
| Main Material | Multiple main materials separated by „/“. |
| Speed | In min⁻¹. Multiple speeds separated by comma. |
| Filter Area | In m². |
| Heat Exchange Area | In m². |
| Fill Level | Value range 0.001 to 1. |
| SB Side | „I“ or „O“ to identify the volume for holdup calculation. |
| Field | Description |
|---|---|
| Asset Name T4 | Designations for Tab. 4 according to SIA conventions. |
| Safety Ref. AT | Three or four digit number (section number in Tab. 5) for „SB“ assets. |
| Material Flow No. liquid | Material flow number of liquid asset content. |
| Material Flow No. gas | Material flow number of gaseous asset content. |
Pre-selections can be made via the list field on the right. Double-click on the record to select.
In the Inventory Number field, the motors assigned to the asset can be identified. Assignment of motors to an asset is done in the „Motors“ function via the reassignment function (A →B).