====== 4.17 {{wvds:i18n>pims_barcode}} Terminal MTL 611 ====== {{wvds:title>04.17 Barcode Terminal}} ===== Scanning a {{wvds:i18n>pims_barcode}} ===== - Attach the scanning stylus adapter to the MTL 611 and open the keyboard - Press **Clear/On** 3 times - Use the down arrow key to go to **PROG** → press **exe** key - Use the right arrow key to go to **START** → press **exe** key - At START A: Use the down arrow key to select **{{wvds:i18n>pims_barcode}}** → press **exe** key - Enter **N**: Transfer existing data to the database - Enter **O**: Accept additional data into MTL611 - Enter **S** to scan, **B** to end - Scan the {{wvds:i18n>pims_barcode}} - Enter the {{wvds:i18n>pims_measuring_point}} (e.g., B-PZ 08151) → press **exe** key - Answer the query with **Y** or **N**, **B** to end - Turn off: Press **Clear/On** 2 times → activate "off" with down arrow (**exe**) - Connect the power adapter for recharging ===== Transfer to Database ===== - Select **Import {{wvds:i18n>pims_barcode}}** in AMED - Turn on MTL 611: Press **Clear/On** 2 times - Use the arrow key to select **"Comms"** → press **exe** - Move cursor to **"Send"** → press **exe** - Move cursor to **"Data"** → press **exe** - At "Send A..": Use down arrow to go to **{{wvds:i18n>pims_barcode}}** → press **exe** - Answer the query on the screen - After the signal tone: Press **Clear/On** 3 times - Use down arrow to go to **Off** → press **exe** ===== Notes ===== ^ Parameter ^ Value ^ | MTL 611 storage capacity | 25 records | | "Comms Link" adapter | Connect to **Com2** interface | | Battery replacement | Only with connected power adapter! | ---- [[.:16-barcode-print|← 4.16 {{wvds:i18n>pims_barcode}} Print]] | [[.:18-pd-output|4.18 {{wvds:i18n>pims_kv}} Output List →]]